Plovdiv Municipality - 10 Eliezer Kalev Str.
The terminal is situated in December 2020. Its located on 10 Eliezer Kalev Str.
Plovdiv Municipality - 10 Eliezer Kalev Str.
The terminal is situated in December 2020. Its located on 10 Eliezer Kalev Str.
Daily indicators:
2025-01-21
 
L24 = 56.9 dBL2424-hour noise level, which is an indicator of the noise associated with discomfort (defined according to the ”Law for protection against environmental noise”)
 
Lnight = 47.8 dBLAnightnight noise level is the A-weighted equivalent noise level averaged over a long period of time, relative to all the night periods in a year, as specified in standard ISO 1996-2:1987
Defined period "night period: (according to the Regulation No 6 of 26 June 2006 for" performance of noise in the environment "): 23- 07 h
 
Lday = 56.7 dBLAdaydaily noise level is the A-weighted equivalent noise level averaged over a long period of time, relative to all the day periods during the year, as specified in the standard BDS ISO 1996-2: 1987;
Defined period "day period" (according to Regulation No 6 of 26 June 2006 on "indicators of environmental noise"): 07-19 h.
 
Lev. = 54.3 dBLAeveningevening level of noise is the A-weighted equivalent noise level averaged over a long period of time, relative to all the evening periods in a year, as specified in standard ISO 1996-2: 1987;
Defined period "evening period: (according to the Regulation No 6 of 26 June 2006 for" performance of noise in the environment "): 19 – 23 h.
 
LAmax = 76.4 dBLAmaxmaximum A-weighted sound level in decibels [dB (A)].
This is the maximum value of the current A-weighted noise level for a given time interval.
 
LAmin = 41.0 dBLAminminimum A-weighted sound level in decibels [dB (A)].
This is the minimum value of the current A-weighted noise level for a given time interval.
 
LAF10 = 57.6 dBLAF10The level of noise along a curve and which has exceeded 10% of the measurement time (T).
The parameter is used as a measure of the noise from the main measured (released) source.
 
LAF90 = 46.1 dBLAF90The noise level in a curve which is exceeded for 90% of the time of measurement (T).